IMPELLER THRUST
Impeller Thrust in the downward direction is due to the unbalanced
discharge pressure across the eye area of the impeller. See
diagram A.

Counteracting this load is an upward force primarily due to the change in direction of the liquid passing through the impeller. The resultant of these two forces constitutes impeller thrust. Calculating this thrust using a thrust constant (K) will often produce only an approximate thrust value because a single constant cannot express the upthrust component which varies with capacity.
To accurately determine impeller thrust, thrust-capacity curves based on actual tests are required. Such curves now exist for the "A" Line. To determine thrust, the thrust factor "K" is read from the thrust-capacity curve at the required capacity and given RPM. "K" is then multiplied by the Total Pump Head (Final Lab Head) times Specific Gravity of the pumped liquid. If impeller thrust is excessively high, the impeller can usually be hydraulically balanced. This reduces the value of "K". Balancing is achieved by reducing the discharge pressure above the impeller eye by use of balancing holes and rings. See diagram B.
NOTE:
Although hydraulic balancing reduces impeller thrust, it also decreases efficiency by 1 to 5 points by providing an addi-tional path for liquid recirculation.
NOTE:
Although hydraulic balancing reduces impeller thrust, it also decreas-es
efficiency by one to five points by providing an additional path for
liquid recirculation. Of even greater concern is that should the
hydraulic balancing holes become clogged, (unclean fluids, fluids
with solid content, intermittent services, etc.), the impeller thrust will
increase and possibly cause the driver to fail. Hydraulically balanced
impellers cannot be used in applications requiring rubber bowl bear-ings
because the flutes on the inside diameter of the bearings pro-vide
an additional path to the top side of the impeller, thus creating
an additional down thrust.
Hydraulically balanced impellers should be used as a "last resort" for those situations where the pump thrust exceeds the motor thrust bearing capabilities.